Surge Protective Device (SPD), also known as Surge Protector, is a nonlinear protective device used in live systems to limit transient overvoltage and guide discharge surge current. It is used to protect electric or electronic systems with low voltage withstand levels from lightning strikes, electromagnetic pulses or operational overvoltage damage. In recent years, electronic information systems (such as television, phone, kommunikation, dator nätverk, etc.) har utvecklats snabbt, och a stort antal av elektronisk information enheter har uppstått och populariserats. Dessa typer av system och utrustning är ofta dyra och viktiga, med låg drift spänning och tål spänning nivåer, making them highly susceptible to lightning electromagnetic pulses. Därför, SPD bör användas för överspänning skydd.


Den överspänning skydd är lämplig för skydd av 220% 2f380V lågspänning effekt matning och är a olinjär komponent. Enligt IEC standarder, den överspänningen skyddet är a enhet huvudsakligen används till undertryck den överspänning och överström av den överföring linjen. The basic requirement for a surge protector to play a protective role is to withstand the expected lightning current and eff extinguish the power frequency continuous current generated after the lightning flow through the maximum clamping voltage of the surge. Det gränser den momentana överspänning som anger den effekt linje eller signal transmission linje till den spänning intervall det den utrustningen eller systemet tål 2c eller urladdningar stark blixt ström till marken till skydda den skyddade utrustningen eller systemet från skada orsakad av påverkan.


De typer och strukturer av överspänning beskyddare variera enligt deras deras olika användningsområden, men de innehåll på minst en olinjär spänning begränsande element. Vanligtvis används överspänning skydd inkluderar MOVs (MetalOxideVaristors) och gas urladdning rör. Elektriska överspänningar innehåll kraftfull energi och kan inte stoppas. För detta orsak, strategin till skydda känslig elektrisk utrustning från överspänning skada är till avled den överspänningen från den utrustningen och sedan flöde in marken.


The surge protector MOV consists of three parts: a metal oxide material in the middle, connected by two semiconductors to the power supply and ground wire. When a surge occurs, the MOV immediately acts with a response time of 1-3 nanoseconds. The "V" in MOV is a rheostat. At the moment of response, the resistance of the MOV drops from its maximum value to almost zero ohms, and overcurrent flows into the ground through the MOV. The protected electrical equipment continues to operate at normal operating voltage. Its semiconductor components have the property of changing resistance with voltage changes. When the voltage drops below a specific value, the movement of electrons in a semiconductor generates high resistance. On the contrary, when the voltage exceeds this specific value, the motion of electrons will change, and the semiconductor resistance will decrease to nearly zero ohms. The voltage is normal, and the surge protector MOV is idle on the side, without affecting the power line.

 


(1) Clamping voltage: represents the voltage value that will cause the MOV to connect to the ground wire. The lower the clamping voltage, the better the protection performance.


(2) Energi absorption/dissipation kapacitet: Detta nominellt värde representerar hur mycket energi den överspänning beskyddare kan absorbera före vara brännas ner, in joule. Den högre den värdet, den bättre den skydd prestanda.


(3) Response time: Surge protectors do not immediately disconnect, and there will be a slight delay in their response to surges.


En annan gemensam överspänning skydd enhet är a gas urladdning rör. Dessa gas urladdning rör har samma funktion som MOVs, flyttar överskott ström från den live tråd till den jord tråd, och uppnår denna funktion av använder inert gas som a ledare mellan de två ledningar. När den spänningen är in a specifikt intervall, den sammansättningen av den gas bestämmer att den är a dålig ledare. Om den spänningen överspänningar och överskrider detta intervall, den styrkan av den strömmen kommer vara tillräcklig till jonisera den gas, göra den gas urladdning rör a mycket bra ledare. It kommer att leda ström till den jord tråd tills den spänningen återgår till normal nivåer, och då blir a defekt ledare.

 